When something in Octiga isn’t behaving as you expect, find the symptom below for its usual cause and fix.
CauseAfter the client’s Global Administrator consents, Octiga registers the tenant and reads its directory, which usually takes a few minutes. Until then its card on the Tenants screen shows Connecting…, and it becomes the tenant’s own card once it’s connected.
FixGive it time. If the card is still connecting an hour later, contact support with the tenant’s name.
CauseThe admin who opened the consent link declined it, or signed in with an account that isn’t a Global Administrator of the tenant you meant to connect.
FixCreate a new consent link, because each link works once and expires after 24 hours. Select Generate new link in the card’s ⋮ menu if it shows Consent declined or Link expired, or start again from + Tenant. Ask the person opening it to sign in as a Global Administrator of the right tenant before approving.
CauseConsent came back, but Octiga couldn’t add the tenant: the tenant is already connected to a different Octiga account, Octiga couldn’t finish registering it, or it’s already on your account but disabled or retained.
FixA tenant on a different Octiga account has to be disconnected there before you can connect it here. If registration didn’t finish, try again, and contact support if it happens again. Consenting again doesn’t restore a disabled or retained tenant, so contact support for that.
CauseThe Tenants list and the tenant’s Tenant settings show Issues detected when Octiga’s last health check for the tenant is more than 36 hours old, found that Octiga’s management application is no longer in the client’s tenant, or couldn’t reach Microsoft Graph.
FixOpen the tenant’s Monitoring page and hover the beacon beside Event monitoring for what’s wrong, which checks failed and when the tenant was last checked. If the beacon is unlit and its tooltip says event monitoring is switched off for this tenant, it doesn’t list the checks, so contact support with the tenant’s name. If the management application is missing, check in Microsoft Entra that the client hasn’t removed or disabled it, and contact support to reconnect the tenant. If the check is out of date, see Status unknown under Monitoring health.
CauseOctiga’s health check couldn’t sign in to Exchange Online for this tenant. Hovering the beacon beside Event monitoring on the tenant’s Monitoring page says Octiga couldn’t reach the tenant, and lists Exchange Online sign-in under Failing checks. The Tenants list doesn’t flag this one.
FixCheck that the management application still holds its Exchange Administrator role and hasn’t been blocked in Exchange Online.
CauseOctiga syncs on a schedule, not continuously. Users, groups, roles and Entra ID policies usually reflect a change within about an hour; Exchange Online, SharePoint and mailbox details can take longer.
FixWait for the next sync. Apart from Recheck on a tenant’s Account risks page, which asks Octiga to re-read the tenant’s user accounts now, there’s no way to force an immediate sync.
CauseA change made directly in Microsoft 365, rather than through Octiga, is picked up at the next sync for that resource, or sooner where Octiga receives Microsoft’s change notifications for it.
FixGive it a sync cycle. A change made through Octiga itself (a save or a remediation) usually shows its new verdict within a couple of minutes, because Octiga re-checks what it has just written.
CauseOctiga is waiting for the first verdict on what you wrote. On the tenant’s Org-level tab the status reads Checking… until the verdict arrives, usually within seconds, sometimes after a couple of minutes. For a user-level baseline, the user’s dot on the User-level tab pulses grey until the verdict arrives, and the user’s side sheet shows a spinner.
FixOn the Org-level tab, give it a couple of minutes. If the row then shows a dash with the tooltip Not assessed, reload the tab to pick up the verdict when it arrives. The User-level tab stops checking for the verdict after about half a minute, so if a user’s dot is still pulsing after that, reload the tab.
The beacon beside Event monitoring on a tenant’s Monitoring page shows the tenant’s monitoring health. Hover it for a sentence saying what’s wrong, any failing checks and when the tenant was last checked. The entries below are named after the states listed in Events; match the tooltip’s sentence to an entry’s cause.
CauseThe Unified Audit Log is switched off in the client tenant, so Microsoft isn’t recording the events Octiga collects.
CauseThe tenant is reachable and auditing, but the Microsoft 365 Management API subscriptions that feed Octiga aren’t in place, so no events are being collected.
FixThis clears once the subscription is restored at the next check cycle. If it doesn’t, contact support.
CauseThe tenant’s last health check is too old to rely on: more than 36 hours. Checks run every six hours, so this usually means the tenant has dropped out of the check cycle rather than missed a run, and it won’t clear by waiting. The Tenants list shows the tenant as Issues detected too.
CauseAt the last health check, Octiga couldn’t reach Microsoft Graph, the management application’s service principal or Exchange Online sign-in for this tenant. The beacon’s tooltip lists which under Failing checks.
FixThis usually clears at the next check. If it doesn’t, check that the client hasn’t revoked Octiga’s application in Microsoft Entra, and that none of the directory roles listed in What Octiga needs from your tenant have been removed. For an Exchange Online sign-in failure, see the Exchange sign-in entry under Connection.
CauseThe tenant has just connected, and Octiga hasn’t run its first health check yet.
FixNothing needs fixing. Octiga runs the first check a few minutes after the tenant connects, or at the latest at its next scheduled check, within six hours. The beacon updates after it.
CauseEvent monitoring is switched off for this tenant, so Octiga doesn’t collect its audit events, and the beacon is unlit. This isn’t a fault.
CauseThe tenant isn’t active in Octiga (for example, it’s disabled, retained or being removed), so monitoring doesn’t run for it, and the beacon is unlit. An inactive tenant isn’t shown on the Tenants list either.
CauseOn an org-level deploy, a baseline that needs a value specific to the tenant is left out unless you fill it in on the Set tenant values step; ticking Skip there leaves it out. When you deploy to users, a user who doesn’t hold the licence a baseline needs is left out of that baseline. Neither counts as a failure. After an org-level deploy, the message counts the baselines you filled in or skipped on Set tenant values and names any Octiga couldn’t add; after an org-level Copy and detach, it also counts the baselines copied from the scheme.
FixCompare the tenant’s Org-level tab with the scheme. For a baseline that needs a tenant value (the scheme’s Requires input column shows Needs a tenant value), deploy again and fill in its fields on Set tenant values. For a user, check Licence requirements for the licence that baseline needs.
CauseUsually the user doesn’t hold the licence a baseline needs, so Octiga leaves them out of that baseline’s checks rather than reporting them as failing. Less often, the data Octiga needs to evaluate that baseline isn’t available for the user.
FixNothing needs fixing in Octiga. If you want the baseline evaluated for this user, assign them the licence it needs.
CauseDeviations follow sync. A fix made directly in Microsoft 365 shows once the next sync (or the relevant change notification) reaches Octiga, not the moment you make it.
FixGive it a sync cycle before assuming the fix didn’t take.
CauseA remediation fails when Microsoft refuses the change, when a temporary error such as throttling lasts through five attempts, or when Octiga finds the setting still doesn’t match after the change. It’s skipped when Octiga doesn’t attempt it, for example because the baseline is already passing or Octiga couldn’t verify the setting’s current state.
FixRead the reason on the error message, which names the baseline and quotes Microsoft or Octiga, or select the row in the remediation progress panel to see it again. Correct what it names, such as a missing licence or a conflicting setting in Microsoft 365, then select Remediate again. Skipped — already passing needs nothing. Remediation applied — awaiting confirmation isn’t a failure: give it a few minutes and check again.
CauseOn the tenant’s Org-level tab, either the tenant’s Allow auto-remediation setting is off, so no baseline on the tenant can remediate automatically, or the baseline comes from a scheme, which sets its Auto switch. Hovering the switch says which: Needs Allow auto-remediation on in Tenant settings, or Managed by and the scheme’s name.
FixFor the tenant setting, select Open Tenant settings in that message and turn on Allow auto-remediation. For a scheme’s baseline, change its Auto switch on the scheme’s page, which applies it to every tenant the scheme manages. Both need L2 Support or Admin.
CauseA tenant can be managed by only one org-level scheme at a time, so deploying a different scheme as managed replaces the current one. The deploy wizard warns you under the tenant, then asks Replace this scheme? before it deploys.
FixTo swap schemes, select Replace and deploy: the tenant leaves its current scheme and follows the new one in one action. To leave it as it is, select Keep scheme, which stops the deploy.
CauseYou chose Copy and detach for a group a scheme manages. A group can’t follow one scheme while also holding a separate copy, so copying baselines onto it detaches it, and later changes to the scheme no longer reach it. The wizard asks Detach this group? first.
FixSelect Detach and deploy if that’s what you want, or Keep scheme to leave the group following its scheme. The scheme’s baselines on the group are replaced by the ones you copy, so any you didn’t pick are removed; baselines added to the group by hand stay. Detaching needs L2 Support or Admin: if the deploy fails with “Your role may not detach a baseline from its scheme”, ask an L2 Support or Admin user to run it.
CauseOctiga shows We couldn’t find your Octiga account when the Microsoft account you signed in with isn’t in any of your MSP’s access groups, or isn’t the account Octiga knows you by.
FixSelect Use another account and sign in with the Microsoft account you use for Octiga. If that’s already the right account, ask an Admin or L2 Support user to add it to an access group; see Access controls. If Octiga says Your sign-in wasn’t accepted instead, select Sign in again.
CauseL1 Read and L1 Read/Write reach only the tenants assigned to their groups. This is enforced on the server, so a tenant outside your groups’ assignment doesn’t appear for you anywhere, including in your alerts. For every role, the Tenants list shows only connected tenants (including those with Issues detected), so a tenant that’s still connecting, or is disabled, retained or being removed, isn’t listed.
FixAsk an Admin or L2 Support user to add the tenant to one of your groups. For a tenant that’s still connecting, see the first entry under Connection; for a disabled or retained tenant, contact support.
CauseThe tenant isn’t assigned to any of your groups, or your role can’t view it. A link to an address with no tenant in your organisation shows Tenant not found instead.
FixAsk an Admin or L2 Support user to add the tenant to one of your groups. For Tenant not found, check the link, or select Go to Tenants and choose the tenant there.
CauseOctiga leaves what your role can’t reach out of the sidebar and Settings rather than showing it greyed out, so a missing section is one your role doesn’t include.
FixCheck Roles and permissions for what each role can see. If you need more, ask an Admin or L2 Support user to change your group’s role.
CauseYour role can open this page but can’t take that action. Hovering the control says what it needs: Needs an L2 or Admin role, or Needs read/write access.
FixAsk someone with that role to do it, or ask an Admin or L2 Support user to add you to a group with that role.
CauseUsually one of three things: the severity you’re alerting at has no priority mapped for that vendor (an empty priority means no ticket is filed), the connection to the PSA is failing its check, or the integration has been disconnected.
FixOpen Settings, then Integrations, and open the PSA. Connection failing comes with a message giving the reason; if the PSA rejected Octiga’s credentials, select Edit connection to update them. Disconnected means ticket sending is paused: select Reconnect to resume it, with no credentials needed. Then check the priority mapping for the alert’s severity.
CauseOctiga couldn’t generate the report. If you were watching it run, the Report failed window gives the reason. A scheduled report that failed wasn’t sent to anyone.
FixSelect Retry in that window, or from the report’s menu in the list. A scheduled report’s menu offers Retry & send instead, which also emails the report to its recipients and needs L2 Support or Admin; Run again generates it without sending it.
CauseOctiga keeps each report’s PDF for a limited time. After that, the report moves to the Expired tab, listed for the record only.
FixCreate a new report for the same dates with New report.